The timing model

The functional model says what FIRAccel computes; the timing model says how long and what it pends on. For rowwise FIR it is FIRTiming (fir.py), and its defining property is that it is physical and near-fit-free — almost everything is a known constant or an exact rate, with a single calibrated curve.

The decomposition

The whole-kernel latency for one command composes as:

whole = (n_col + T) + trips + n_row·row_depth(n_col) + fill_const
        └ fill        └ II=1   └ per-row pipeline      └ one
          (first row)   compute   (the one fitted curve)  scalar

with trips = n_row·(n_col − T + 1). Three of the four terms are not fitted:

  • Channel occupancy is deterministic. Each transferred word is one bus beat at II=1, so the X-read / Y-write occupancy is simply the word count (+ a 2-cycle per-burst address setup). The port carries this as a bus_timing, and the slice calls supply only num_trans = n_row. (See transfer-beat occupancy.)
  • Compute is exactly II=1. compute_body = trips + (n_row−1)·row_depth — the MAC sustains one output per cycle (validated to R²=1.0 on single-row points).
  • fill_const is one scalar — the command→first-bus latency and drain edge.

The only fitted term is row_depth(n_col) — the per-row pipeline / 2-buffer ping-pong refill depth — carried as a saturating InterpCalibModel lookup, not a basis-function fudge. How it (and fill_const) are measured and fit is Fitting the model.

The store hides under compute

The key timing trick is on the store: the Y-write is early-anchored at the time the first output row is ready, and given a floor of compute_body, so it occupies the write channel for max(write_occ, compute_body). When compute is the bottleneck, the store finishes under compute’s shadow — overlapping the X-read instead of running after it. Successive stores serialize by their effective spans, so back-to-back throughput stays correct. This is max(load, compute, store) made explicit on the store side.

Where the events are logged

To validate against RTL you compare event timelines, so each stage emits a timestamped event. The rule: a begin/end pair around every bus-visible transfer, plus the command arrival as the anchor.

event logged at bus-visible in cosim?
cmd_arrive the loader pulls the command the anchor (t = 0)
load_begin / load_end around the X-read yes — the X-read span
comp_begin compute starts no — sim-internal
store_begin / store_end around the Y-write yes — the Y-write span
resp_sent the response burst yes

The bus-visible events are exactly what the VCD extractor recovers from cosim, so both timelines are anchored at cmd_arrive and compared offset-by-offset — the comparison the calibration gates report.